Professional reference · source-specific

Keep the
assembly in view.

Manufacturer document transcriptions include media-only, cabinet and upgrade-rail contexts. They are not a single comparable dataset. Open a specific source table and keep its scope attached.

209 linked-source observations, including held readings. Additional unlinked archived tables remain private pending public-source verification. A repeated document is not another independent test. Restricted PDF copies are not redistributed.

Model 216 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 16 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 216 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.06usable source pointdoc-pressure-0472
6000.09usable source pointdoc-pressure-0473
8000.13usable source pointdoc-pressure-0474
10000.17usable source pointdoc-pressure-0475
12000.23usable source pointdoc-pressure-0476
14000.29usable source pointdoc-pressure-0477
1600 *0.36usable source pointdoc-pressure-0478
Model 416 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 16 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 416 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.07usable source pointdoc-pressure-0479
6000.1usable source pointdoc-pressure-0480
8000.13usable source pointdoc-pressure-0481
10000.18usable source pointdoc-pressure-0482
12000.24usable source pointdoc-pressure-0483
1400 *0.31usable source pointdoc-pressure-0484
Model 516 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 16 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 516 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.04usable source pointdoc-pressure-0485
6000.05usable source pointdoc-pressure-0486
8000.07usable source pointdoc-pressure-0487
10000.09usable source pointdoc-pressure-0488
12000.1usable source pointdoc-pressure-0489
14000.13usable source pointdoc-pressure-0490
16000.15usable source pointdoc-pressure-0491
18000.18usable source pointdoc-pressure-0492
20000.21usable source pointdoc-pressure-0493
22000.24usable source pointdoc-pressure-0494
24000.27usable source pointdoc-pressure-0495
2600 *0.31usable source pointdoc-pressure-0496
Model 213CBN · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13+ · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 213CBN · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.04usable source pointdoc-pressure-0497
6000.07usable source pointdoc-pressure-0498
8000.1usable source pointdoc-pressure-0499
10000.13usable source pointdoc-pressure-0500
12000.17usable source pointdoc-pressure-0501
14000.21usable source pointdoc-pressure-0502
16000.25usable source pointdoc-pressure-0503
18000.3usable source pointdoc-pressure-0504
2000 *0.35usable source pointdoc-pressure-0505
Model 413CBN · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13+ · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 413CBN · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.04usable source pointdoc-pressure-0506
6000.07usable source pointdoc-pressure-0507
8000.1usable source pointdoc-pressure-0508
10000.14usable source pointdoc-pressure-0509
12000.19usable source pointdoc-pressure-0510
14000.24usable source pointdoc-pressure-0511
16000.29usable source pointdoc-pressure-0512
18000.36usable source pointdoc-pressure-0513
2000 *0.43usable source pointdoc-pressure-0514
Model 513CBN · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13+ · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 513CBN · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.03usable source pointdoc-pressure-0515
6000.04usable source pointdoc-pressure-0516
8000.05usable source pointdoc-pressure-0517
10000.07usable source pointdoc-pressure-0518
12000.08usable source pointdoc-pressure-0519
14000.1usable source pointdoc-pressure-0520
16000.12usable source pointdoc-pressure-0521
18000.15usable source pointdoc-pressure-0522
20000.17usable source pointdoc-pressure-0523
22000.2usable source pointdoc-pressure-0524
24000.22usable source pointdoc-pressure-0525
26000.25usable source pointdoc-pressure-0526
28000.29usable source pointdoc-pressure-0527
3000 *0.32usable source pointdoc-pressure-0528
Model 113 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Source curves for this model disagree. Entire model curve held from quantitative comparisons pending context/revision resolution. · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 113 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
200Withheldsource conflict holddoc-pressure-0529
400Withheldsource conflict holddoc-pressure-0530
600Withheldsource conflict holddoc-pressure-0531
800Withheldsource conflict holddoc-pressure-0532
1000Withheldsource conflict holddoc-pressure-0533
1200 *Withheldsource conflict holddoc-pressure-0534
Model 213 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 213 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0535
4000.04usable source pointdoc-pressure-0536
6000.06usable source pointdoc-pressure-0537
8000.09usable source pointdoc-pressure-0538
10000.12usable source pointdoc-pressure-0539
12000.15usable source pointdoc-pressure-0540
14000.19usable source pointdoc-pressure-0541
16000.23usable source pointdoc-pressure-0542
18000.27usable source pointdoc-pressure-0543
2000 *0.31usable source pointdoc-pressure-0544
Model 313 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 313 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.03usable source pointdoc-pressure-0545
4000.05usable source pointdoc-pressure-0546
6000.09usable source pointdoc-pressure-0547
8000.13usable source pointdoc-pressure-0548
10000.17usable source pointdoc-pressure-0549
1200 *0.23usable source pointdoc-pressure-0550
Model 413 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 413 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0551
4000.05usable source pointdoc-pressure-0552
6000.07usable source pointdoc-pressure-0553
8000.1usable source pointdoc-pressure-0554
10000.14usable source pointdoc-pressure-0555
12000.17usable source pointdoc-pressure-0556
14000.22usable source pointdoc-pressure-0557
16000.26usable source pointdoc-pressure-0558
18000.31usable source pointdoc-pressure-0559
2000 *0.37usable source pointdoc-pressure-0560
Model 513 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 513 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.01usable source pointdoc-pressure-0561
4000.02usable source pointdoc-pressure-0562
6000.04usable source pointdoc-pressure-0563
8000.05usable source pointdoc-pressure-0564
10000.05usable source pointdoc-pressure-0565
12000.07usable source pointdoc-pressure-0566
14000.08usable source pointdoc-pressure-0567
16000.1usable source pointdoc-pressure-0568
18000.11usable source pointdoc-pressure-0569
20000.13usable source pointdoc-pressure-0570
22000.15usable source pointdoc-pressure-0571
24000.17usable source pointdoc-pressure-0572
26000.18usable source pointdoc-pressure-0573
28000.2usable source pointdoc-pressure-0574
3000 *0.23usable source pointdoc-pressure-0575
Model 613 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Source curves for this model disagree. Entire model curve held from quantitative comparisons pending context/revision resolution. · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 613 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
200Withheldsource conflict holddoc-pressure-0576
400Withheldsource conflict holddoc-pressure-0577
600Withheldsource conflict holddoc-pressure-0578
800Withheldsource conflict holddoc-pressure-0579
1000Withheldsource conflict holddoc-pressure-0580
1200Withheldsource conflict holddoc-pressure-0581
1400Withheldsource conflict holddoc-pressure-0582
1600Withheldsource conflict holddoc-pressure-0583
1800Withheldsource conflict holddoc-pressure-0584
2000 *Withheldsource conflict holddoc-pressure-0585
Model 813 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 813 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0586
4000.04usable source pointdoc-pressure-0587
6000.06usable source pointdoc-pressure-0588
8000.09usable source pointdoc-pressure-0589
10000.12usable source pointdoc-pressure-0590
12000.15usable source pointdoc-pressure-0591
14000.19usable source pointdoc-pressure-0592
16000.23usable source pointdoc-pressure-0593
18000.27usable source pointdoc-pressure-0594
2000 *0.31usable source pointdoc-pressure-0595
Model 913 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 13 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Source curves for this model disagree. Entire model curve held from quantitative comparisons pending context/revision resolution. · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 913 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
200Withheldsource conflict holddoc-pressure-0596
400Withheldsource conflict holddoc-pressure-0597
600Withheldsource conflict holddoc-pressure-0598
800Withheldsource conflict holddoc-pressure-0599
1000Withheldsource conflict holddoc-pressure-0600
1200Withheldsource conflict holddoc-pressure-0601
1400Withheldsource conflict holddoc-pressure-0602
1600Withheldsource conflict holddoc-pressure-0603
1800 *Withheldsource conflict holddoc-pressure-0604
Model 110 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 110 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0605
4000.05usable source pointdoc-pressure-0606
6000.06usable source pointdoc-pressure-0607
8000.1usable source pointdoc-pressure-0608
10000.14usable source pointdoc-pressure-0609
1200 *0.2usable source pointdoc-pressure-0610
Model 210 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 210 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0611
4000.03usable source pointdoc-pressure-0612
6000.04usable source pointdoc-pressure-0613
8000.06usable source pointdoc-pressure-0614
10000.08usable source pointdoc-pressure-0615
12000.11usable source pointdoc-pressure-0616
14000.13usable source pointdoc-pressure-0617
16000.16usable source pointdoc-pressure-0618
18000.19usable source pointdoc-pressure-0619
2000 *0.22usable source pointdoc-pressure-0620
Model 310 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 310 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0621
4000.04usable source pointdoc-pressure-0622
6000.06usable source pointdoc-pressure-0623
8000.1usable source pointdoc-pressure-0624
10000.14usable source pointdoc-pressure-0625
1200 *0.19usable source pointdoc-pressure-0626
Model 410 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 410 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0627
4000.03usable source pointdoc-pressure-0628
6000.05usable source pointdoc-pressure-0629
8000.07usable source pointdoc-pressure-0630
10000.09usable source pointdoc-pressure-0631
12000.12usable source pointdoc-pressure-0632
14000.15usable source pointdoc-pressure-0633
16000.19usable source pointdoc-pressure-0634
18000.22usable source pointdoc-pressure-0635
2000 *0.27usable source pointdoc-pressure-0636
Model 510 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 510 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0637
4000.02usable source pointdoc-pressure-0638
6000.03usable source pointdoc-pressure-0639
8000.04usable source pointdoc-pressure-0640
10000.04usable source pointdoc-pressure-0641
12000.05usable source pointdoc-pressure-0642
14000.06usable source pointdoc-pressure-0643
16000.07usable source pointdoc-pressure-0644
18000.09usable source pointdoc-pressure-0645
20000.1usable source pointdoc-pressure-0646
22000.12usable source pointdoc-pressure-0647
24000.14usable source pointdoc-pressure-0648
26000.15usable source pointdoc-pressure-0649
28000.17usable source pointdoc-pressure-0650
3000 *0.19usable source pointdoc-pressure-0651
Model 610 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Source curves for this model disagree. Entire model curve held from quantitative comparisons pending context/revision resolution. · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 610 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
200Withheldsource conflict holddoc-pressure-0652
400Withheldsource conflict holddoc-pressure-0653
600Withheldsource conflict holddoc-pressure-0654
800Withheldsource conflict holddoc-pressure-0655
1000Withheldsource conflict holddoc-pressure-0656
1200Withheldsource conflict holddoc-pressure-0657
1400Withheldsource conflict holddoc-pressure-0658
1600Withheldsource conflict holddoc-pressure-0659
1800Withheldsource conflict holddoc-pressure-0660
2000 *Withheldsource conflict holddoc-pressure-0661
Model 810 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 810 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
2000.02usable source pointdoc-pressure-0662
4000.03usable source pointdoc-pressure-0663
6000.04usable source pointdoc-pressure-0664
8000.06usable source pointdoc-pressure-0665
10000.08usable source pointdoc-pressure-0666
12000.11usable source pointdoc-pressure-0667
14000.13usable source pointdoc-pressure-0668
16000.16usable source pointdoc-pressure-0669
18000.19usable source pointdoc-pressure-0670
2000 *0.22usable source pointdoc-pressure-0671
Model 910 · filter_media · aprilaire-doc-001 · cabinet not specified

AprilAire Air Cleaner Installation & Owner’s Manual — Models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, 2416 · archived revision 12.23 · page 3

filter_media · 11 · Within source chart only; actual test/cabinet/loading conditions not supplied · 12.23 · Highest value shown is maximum recommended airflow capacity.

Official manufacturer source · current linked bytes/revision may differ.

aprilaire-doc-001 · model 910 · separate source table
Airflow (CFM)Pressure drop (in. w.c.)Disposition
4000.03usable source pointdoc-pressure-0672
6000.05usable source pointdoc-pressure-0673
8000.07usable source pointdoc-pressure-0674
10000.09usable source pointdoc-pressure-0675
12000.12usable source pointdoc-pressure-0676
14000.15usable source pointdoc-pressure-0677
16000.18usable source pointdoc-pressure-0678
18000.22usable source pointdoc-pressure-0679
2000 *0.27usable source pointdoc-pressure-0680

Read the comparison and correction policy →